      Human Interleukin 6 (IL-6)

      FOR RESEARCH USE ONLY
      Assay range0.2 pg/ml -8 pg/ml               96determinations
      Purpose
      This kit allows for the determination ofIL-6concentrations in Humanserum, cellculture supernates and other biological fluids
       
      Principle of the assay
      The kit assay Human Interleukin 6(IL-6)level in the sampleuse Purified Human Interleukin 6(IL-6)antibody to coat microtiter plate wells, make solid-phase antibody, then addInterleukin 6(IL-6)to wells,Combined antibody which With HRP labeled goat anti- Human become antibody - antigen - enzyme-antibody complex, after washing Compley,Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed,reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of  Human Interleukin 6(IL-6)in the samples is then determined by comparing the O.D. of the samples to the standard curve.
      Materials provided with the kit

      1
      wash solution
      20ml×1bottle
      7
      Stopp Solution
      6ml×1 bottle
      2
      HRP-Conjugate reagent
      6ml×1 bottle
      8
      Standard16pg/ml
      0.5ml×1 bottle
      3
      Microelisa stripplate
      12well×8strips
      9
      Standard diluent
      1.5ml×1bottle
      4
      Sample diluent
      6ml×1 bottle
      10
      Instruction
      1
      5
      Chromogen Solution A
      6ml×1 bottle
      11
      Closure plate membrane
      2
      6
      Chromogen Solution B
      6ml×1 bottle
      12
      Sealed bags
      1

      Specimen requirements
      1.       extractas soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
      2.       Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
      Assay procedure
      1.       Dilute and add sample:Dilute Original density Standard as follow table:

      8 pg/ml
      5 Standard
      150μl Original density Standard+150μl Standard diluent
      4pg/ml
      4 Standard
      150μl 5 Standard+150μl Standard diluent
      2 pg/ml
      3 Standard
      150μl 4 Standard+150μl Standard diluent
      1 pg/ml
      2 Standard
      150μl 3 Standard +150μl Standard diluent
      0.5 pg/ml
      1 Standard
      150μl 2 Standard +150μl Standard diluent

      2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
      3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.
      4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
      5.washingUncover Closure plate membrane, discardLiquid, dry by swing, add washing buffer to every well, still for 30s then drain,repeat 5 times, dry by pat.
      6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well.
      7.incubateOperation with 3.
      8.washingOperation with 5.
      9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37
      10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
      11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
      Steps description

      Standard, Sample diluent

       

      AddStandard, Sample diluent, incubate for 30 min at 37.

       

      Wash 5 time,AddHRP-Conjugate reagent, incubate for 30 min at 37.

       

      Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

       

      AddStopp Solution

       

      Read absorbance at 450nm within 15 min

       

      calculate

      Calculate
      Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.
      Important notes
      1.       The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
      2.       washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
      3.       add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
      4.       if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluenteand multiplied by the dilution factor.×n×5.
      5.       Closure plate membrane only limits the disposable use, to avoid cross-contamination.
      6.       The substrate evade the light preservation.
      7.       Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
      8.       All samples, washing buffer and each kind of reject should according to infective material process.
      9.       Do not mix reagents with those from other lots.
       
      Storage and validity
      1Storage 2-8℃.
      2validity six months.
       

      聯(lián)


      主站蜘蛛池模板: 色一情一伦一区二区三| 91精品国产人妻一区二区三区| 日韩高清在线亚洲专区国产| 日韩无套内射视频6| 江陵县| 亚洲AV日韩专区在线观看| 日韩人妻无码精品专区906188| 精品乱码一区内射人妻无码| 夜色资源站www国产在线观看| 久久久亚洲欧洲日产国产成人无码| 99国精品午夜福利视频不卡99| 日本三码电影在线| 色妞www精品免费视频| 亚洲日韩乱码中文无码蜜桃臀网站| 久久亚洲一区二区三区四区| 精品国产av无码一区二区三区| 国产激情一区二区三区在线蜜臀| 熟妇人妻久久精品一区二区| 五月天亚洲色图| 小婕子伦流澡到高潮h| 国产96AV在线播放视频| 在线观看欧美一区二区三区| 日本午夜网站| 最新国自产拍av| 国产精品毛片大码女人| 国产日产精品系列| a级毛片免费播放| 国产ChineseHD精品| 亚洲色小说| 国产成AV人片久青草影院| 无码精品国产D在线观看| 久久免费看少妇a级黄片| 日韩精品成人无码专区免费| 国产一区二区三区高清视频| 日韩a视频| 白嫩少妇bbw撒尿视频| 国产一卡2卡3卡四卡网站| 国产桃色在线成免费视频| 欧洲av无码放荡人妇网站| 99热门精品一区二区三区无码| 在线视频精品中文无码|